SATIP INDEX - HVAC
1 Centrfugal & Axial Fan : SATIP-K-001-01
Exhaust and Supply Fan Receiving, Handling, Storage and Preservation Inspect - SAIC-K-4001
Exhaust and Supply Fan Installation Inspection - SAIC-K-4002
Air Moving / Cooling Equipment Duct / Pipe Connection Installation inspection - SAIC-K-4003
2 Air Handling Units : SATIP-K-001-02
Air Handling Unit Receiving, Handling, Storage and Preservation Inspection - SAIC-K-4004
AHU Installation Inspection - SAIC-K-4005
Essential Operating Facilities HVAC Requirements - SAIC-K-4006
Condensate Drain Lay-out Inspection - SAIC-K-4007
Pressurized Building HVAC Requirements - SAIC-K-4044
Communication Facilities HVAC Requirements - SAIC-K-4045
Battery Room HVAC Requirements - SAIC-K-4046
3 HVAC Metal Duct System : SATIP-K-001-03
Metal Duct, Metal Duct Insulation & Metal Duct Hangers and Supports Receiving - SAIC-K-4008
Air Terminal Devices and Duct System Accessories Receiving - SAIC-K-4009
Fire Damper Receiving Inspection - SAIC-K-4010
Ducting System Storage, Handling and Preservation - SAIC-K-4011
Metal Duct Hangers and Supports Installation - SAIC-K-4012
Metal Duct Installation Inspection - SAIC-K-4013
Metal Grease Duct - SAIC-K-4014
Metal duct Insulation Installation Inspection - SAIC-K-4015
Metal duct System accessories Installation Inspection - SAIC-K-4016
Air Terminal Devices Installation Inspection - SAIC-K-4017
Fire Damper Installation Inspection - SAIC-K-4018
Fire Damper Functional / Closure Test - SATR-K-4001
4 Chilled Water Piping : SATIP-K-001-04
Chilled Water Piping lay-out and Supports Installation Inspection - SAIC-K-4020
Chilled Water Piping two-way and Three Way Control Valve Arrangement Installation Inspection - SAIC-K-4021
Closed Chilled Water Treatment Test - SATR-K-4002
5 Chilled Water System : SATIP-K-001-05
Chilled Water System Components Receiving Inspection - SAIC-K-4022
Chilled Water System Components Installation - SAIC-K-4023
6 Refrigerant Piping : SATIP-K-001-07
Refrigerant Receiving, Storage, Handling and Preservation Inspection - SAIC-K-4025
Refrigerant Piping, Fittings and Support Lay-out Installation Inspection - SAIC-K-4026
Air Moving / Cooling Valve and Apparatus Arrangement Installation Inspection - SAIC-K-4027
Refrigerant Piping Pressure Test - SATR-K-4003
Refrigerant Piping Vacuum Test - SATR-K-4004
7 Air Filtration Devices : SATIP-K-001-08
Filter Receiving, Handling, Storage and Preservation Inspection - SAIC-K-4028
Filter Installation Inspection - SAIC-K-4029
Grease Filter Installation Inspection - SAIC-K-4030
8 Through-the Wall and Window-Mounted Air Conditioners : SATIP-K-001-09
Wall Mounted Air Conditioner Receiving, Handling, Storage and Preservation Insp. - SAIC-K-4031
Wall Mounted Air Conditioner Installation Inspection - SAIC-K-4032
9 Air Ventilation/Cooling Systems (Exhaust Hoods and Passively Cooled Shelters) : SATIP-K-001-10
Local Exhaust Hood Receiving, Handling, Storage and Preservation Inspection - SAIC-K-4033
Passively Cooled Shelter Receiving - SAIC-K-4034
Passively Cooled Shelter Installation - SAIC-K-4035
Exhaust Hood Installation Inspection - SAIC-K-4036
Exhaust Hood Test - SATR-K-4005
10 A/C Split System : SATIP-K-001-11
Air Cooled Condenser Receiving, Handling, Storage and Preservation Receiving Inspection - SAIC-K-4037
Fan Coil Receiving, Handling, Storage and Preservation Inspection - SAIC-K-4038
Air Cooled Condenser Installation Inspection - SAIC-K-4039
Fan Coil Installation inspection - SAIC-K-4040
11 Testing, Adjusting and Balancing of HVAC Systems : SATIP-K-001-12
HVAC Systems Testing Organization Qualifications - SAIC-K-4041
HVAC System Testing, Adjusting, and Balancing Procedures Review - SAIC-K-4042
Final Inspection of HVAC Systems - SAIC-K-4043
HVAC System Testing, Adjusting, and Balancing Report - SATR-K-4006