SATIP INDEX - ELECTRICAL
1 AC UPS Systems : SATIP-P-103-01
General - Electronic Equipment, Storage Handling & Preservation - SAIC-P-3001
General - Electrical Equipment, Storage Handling & Preservation - SAIC-P-3002
General - Switchgear Room / Substation, Equipment Pre-Installation Inspection - SAIC-P-3003
UPS/DC Vented Ni-Cad Wet Cell, Storage Handling & Preservation - SAIC-P-3101
UPS/DC Vented Lead-Acid Wet Cell, Storage Handling & Preservation - SAIC-P-3102
UPS/DC Valve Regulated Lead-Acid (VRLA) Gelatin Cell, Storage Handling & Preservation - SAIC-P-3103
UPS/DC Aqueous Sulfuric Acid Electrolyte, Storage Handling & Preservation - SAIC-P-3104
UPS/DC Dry Potassium or Sodium Hydroxide Electrolyte, Storage Handling & Preservation - SAIC-P-3105
UPS DC/AC Inverter, Material Receiving - SAIC-P-3106
UPS Static Switch, Material Receiving - SAIC-P-3107
UPS Transfer Switch Material Receiving - SAIC-P-3108
UPS Bypass Line Transformer Material Receiving - SAIC-P-3109
UPS Maintenance Bypass Switch Material Receiving - SAIC-P-3110
UPS Panelboards / CB's Material Receiving - SAIC-P-3111
UPS/DC Battery Rectifier / Charger Material Receiving - SAIC-P-3112
UPS/DC Vented Ni-Cad Wet Cell Material Receiving - SAIC-P-3113
UPS/DC Vented Lead-Acid Wet Cell Material Receiving - SAIC-P-3114
UPS/DC VRLA Gelatin Cell Material Receiving - SAIC-P-3115
UPS/DC Aqueous Sulfuric Acid Electrolyte Material Receiving - SAIC-P-3116
UPS/DC Dry Potassium or Sodium Hydroxide Material Receiving - SAIC-P-3117
UPS/DC System and Battery Accessories, Material Receiving - SAIC-P-3118
UPS/DC Battery Room, Equipment Pre-Installation Inspection - SAIC-P-3119
UPS/DC Equipment and Battery Rack, Installation and Pre-Commissioning - SAIC-P-3120
UPS/DC System Electrochemical Battery Installation and Pre-Commissioning - SAIC-P-3121
UPS/DC Electrochemical Battery, Storage and Preservation Testing - SATR-P-3101
UPS/DC Vented Ni-Cad Wet Cell, Jobsite Acceptance Test - SATR-P-3102
UPS/DC Vented Lead-Acid Wet Cell, Jobsite Acceptance Test - SATR-P-3103
UPS/DC Valve-Regulated Lead-Acid (VRLA) Gelatin Cell, Jobsite Acceptance Test - SATR-P-3104
UPS DC/AC Inverter, Pre-Commissioning & Functional Testing - SATR-P-3105
UPS Static Switch, Pre-Commissioning & Functional Testing - SATR-P-3106
UPS Transfer Switch, Pre-Commissioning & Functional Testing - SATR-P-3107
UPS Bypass Line Transformer, Pre-Commissioning & Functional Testing - SATR-P-3108
UPS Maintenance Bypass Switch, Pre-Commissioning & Functional Testing - SATR-P-3109
UPS Panelboards / CB's, Pre-Commissioning & Functional Testing - SATR-P-3110
UPS/DC Battery Rectifier / Charger, Pre-Commissioning & Functional Testing - SATR-P-3111
UPS Distribution System, Energized Bolted-Fault Test - SATR-P-3112
UPS/DC Vented Ni-Cad Wet Cell, Battery Pre-Commissioning Test - SATR-P-3113
UPS/DC Vented Lead-Acid Wet Cell, Battery Pre-Commissioning Test - SATR-P-3114
UPS/DC Valve-Regulated Lead-Acid (VRLA) Gelatin Cell, Battery Pre-Commissioning Test - SATR-P-3115
2 Direct Current Power Systems : SATIP-P-103-02
DC Switchboard / CB's, Material Receiving - SAIC-P-3122
DC Panelboard / CB's, Material Receiving - SAIC-P-3123
DC Switchboard / CB's, Pre-Commissioning & Functional Testing - SATR-P-3116
DC Switchboard / CB's, Pre-Commissioning & Functional Testing - SATR-P-3117
0 Low Voltage (600V to 1kV) Cable : SATIP-P-104-01
General - Hazardous Location Conduit and Cable Sealing Special Work Procedure, Document Review - SAIC-P-3004
Cable Storage, Handling, & Preservation - SAIC-P-3201
Low Voltage UL / NEC Power and Control Cable, Material Receiving - SAIC-P-3202
Low Voltage NEC / SASO / IEC Unjacketed Wire, Material Receiving - SAIC-P-3203
Low Voltage IEC Armored Cable, Material Receiving - SAIC-P-3204
Low Voltage IEC Unarmored Cable, Material Receiving - SAIC-P-3205
Low Voltage Power Cable Accessories, Material Receiving - SAIC-P-3206
Low Voltage Power and Control Cable, Installation and Pre-Commissioning - SAIC-P-3207
Low Voltage Building Wire, Installation and Pre-Commissioning - SAIC-P-3208
Hazardous Location Conduit / Cable Seal Fitting Installation and Sealing - SAIC-P-3209
Low Voltage Power and Control Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3201
Low Voltage Building Wire (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3202
Low Voltage Power and Control Cable, Continuity and Megger Insulation Resistance Testing - SATR-P-3203
Low Voltage Building Wire, Continuity and Megger Insulation Resistance Testing - SATR-P-3204
Low Voltage Power and Control Cable, Termination Torque Testing - SATR-P-3205
Low Voltage Building Wire, Termination Torque Testing - SATR-P-3206
3 Medium Voltage (1.0kV to 35kV) Cable : SATIP-P-104-02
Medium Voltage UL / NEC Cable, Material Receiving - SAIC-P-3211
Medium Voltage IEC Cable, Material Receiving - SAIC-P-3212
Medium Voltage Power Cable Accessories, Material Receiving - SAIC-P-3213
Medium Voltage Cable, Installation and Pre-Commissioning - SAIC-P-3214
Medium Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3207
Medium Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3208
Medium Voltage Power Cable, Termination Torque Testing - SATR-P-3209
Medium Voltage Power Cable, High-Potential Withstand Testing - SATR-P-3210
Download SATIP Index xlsx file
4 Cable Tray, Fittings and Accessories : SATIP-P-104-03
Cable Tray and Accessories, Storage Handling & Preservation - SAIC-P-3301
Cable Tray, Metallic Tray Systems, Material Receiving - SAIC-P-3302
Cable Tray, Non-Metallic Tray Systems, Material Receiving - SAIC-P-3303
Cable Tray, Non-Metallic Tray Accessories, Material Receiving - SAIC-P-3305
Cable Tray Firewall Barriers, Material Receiving - SAIC-P-3306
Cable Tray, Metallic Tray Systems, Installation and Pre-Commissioning - SAIC-P-3307
Cable Tray, Non-Metallic Tray Systems, Installation and Pre-Commissioning - SAIC-P-3308
Cable Tray Firewall Barriers, Installation and Pre-Commissioning - SAIC-P-3309
Cable Tray, NEMA VE1 Static Load Testing - SATR-P-3301
5 Boxes (Junction, Terminal and Pull) Wire Troughs & Wireways : SATIP-P-104-04
General Boxes and Enclosures - Material Receiving - SAIC-P-3007
General Boxes and Enclosures - Metallic Wireways and Access, Material Receiving - SAIC-P-3008
General Boxes and Enclosures - Non-metallic Wireways and Access, Material Receiving - SAIC-P-3009
General Boxes and Enclosures - Pushbutton and Pilotlight Control Stations and Access, Material Receiving - SAIC-P-3010
General Boxes and Enclosures - Non-Hazardous Indoor Enclosures, Installation and Pre-Commissioning - SAIC-P-3014
General Boxes and Enclosures - Non-Hazardous Outdoor Enclosures, Installation and Pre-Commissioning - SAIC-P-3015
General Boxes and Enclosures - Class I, Division 1 or Zone 1, Hazardous Location Enclosures (Indoor and Outdoor), Installation, and Pre-Commissioning - SAIC-P-3016
General Boxes and Enclosures - Class I, Division 2 or Zone 2, Hazardous Location Enclosures (Indoor and Outdoor), Installation, and Pre-Commissioning - SAIC-P-3017
6 Above-Grade Conduits, Fittings and Accessories : SATIP-P-104-05
Conduit - Storage, Handling, and Preservation - SAIC-P-3310
Conduit - Galvanized Rigid Steel (GRS) Conduit, Material Receiving - SAIC-P-3311
Conduit - Flexible Metal Conduit (FMC), Material Receiving - SAIC-P-3313
Conduit - Liquid-Tight Flexible Metal Conduit (LT Flex), Material Receiving - SAIC-P-3314
Conduit - Explosion-Proof Flexible Metal Couplings (EXP Flex), Material Receiving - SAIC-P-3315
Conduit - Electrical Metallic Tubing (EMT), Material Receiving - SAIC-P-3316
Conduit - EXP Fittings and Accessories, Material Receiving - SAIC-P-3317
Conduit - EMT & FMC Fittings and Accessories, Material Receiving - SAIC-P-3318
Conduit - GRS Fittings and Accessories, Material Receiving - SAIC-P-3319
Conduit - LT Flex Fittings and Accessories, Material Receiving - SAIC-P-3320
Conduit - Hazardous Location GRS & LT Flex Conduit Systems (Class I, Zone or Div 2), Installation and Pre-Commissioning - SAIC-P-3321
Conduit - Hazardous Location GRS & EXP Flex Conduit Systems (Class I, Zone or Div 1), Installation and Pre-Commissioning - SAIC-P-3322
Conduit - PVC-Coated GRS Conduit Systems (HL and NHL), Installation and Pre-Commissioning - SAIC-P-3323
Conduit - GRS & LT Flex Conduit Systems (NHL), Installation and Pre-Commissioning - SAIC-P-3324
Conduit - EMT & FMC Raceway Systems (NHL), Installation and Pre-Commissioning - SAIC-P-3325
7 Below-Grade Conduit, Fittings and Accessories : SATIP-P-104-07
Pre-cast Ductbank / MH / HH, Jobsite Storage, Handling and Preservation - SAIC-P-3327
Ductbank PVC Conduit, Material Receiving - SAIC-P-3328
Pre-cast Ductbank, Fabrication and Jobsite Material Receiving - SAIC-P-3331
Ductbank / MH / HH Excavation, Trenching, and Backfilling - SAIC-P-3333
Cast-in-Place Ductbank Fabrication - SAIC-P-3334
Manhole / Handhole Fabrication (Pre-Cast and Cast in Place) - SAIC-P-3335
Ductbank Installation and Conduit Termination and Capping - SAIC-P-3336
Ductbank / MH / HH Grounding and Bonding, Installation and Pre-Commissioning - SAIC-P-3337
8 HVAC Equipment : SATIP-P-104-08
HVAC - Control Panel - Material Receiving, Installation and Pre-Commissioning - SAIC-P-3401
HVAC - Air Cooled Condenser - Material Receiving, Installation and Pre-Commissioning - SAIC-P-3402
HVAC - Air Handler Unit (AHU) - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3403
HVAC - Centrifugal and Axial Fan - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3404
HVAC - Air Cooled Chiller - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3405
HVAC - E & I Installation for Pressurized Building Inspection - SAIC-P-3406
HVAC System - De-energized Testing - SATR-P-3401
HVAC System - Energized Functional Testing & Motor Four Hour Run Test - SATR-P-3402
9 Electrical Heat Tracing : SATIP-P-104-09
Heat Tracing - Control Panel - Material Receiving - SAIC-P-3501
Heat Tracing - Thermostat, Ambient - Material Receiving - SAIC-P-3502
Heat Tracing - Thermostat, Capillary Tube & Bulb - Material Receiving - SAIC-P-3503
Heat Tracing - Thermostat, RTD - Material Receiving - SAIC-P-3504
Heat Tracing - Contactor - Material Receiving - SAIC-P-3505
Heat Tracing - Tank Heating Pads - Material Receiving - SAIC-P-3506
Heat Tracing - Instrument Housing - Material Receiving - SAIC-P-3507
Heat Tracing - Mineral Insulated (MI) Cable - Material Receiving - SAIC-P-3508
Heat Tracing - Self-Regulating Cable - Material Receiving - SAIC-P-3509
Heat Tracing - Constant-Wattage Cable - Material Receiving - SAIC-P-3510
Heat Tracing - Power-Limiting Cable - Material Receiving - SAIC-P-3511
Heat Tracing - Cable Accessories - Material Receiving - SAIC-P-3512
Heat Tracing System - Pre-Installation Visual Inspection - SAIC-P-3513
Heat Tracing - Mineral Insulated (MI) Cable - Installation and Pre-Commissioning - SAIC-P-3514
Heat Tracing - Self-Regulating Cable - Installation and Pre-Commissioning - SAIC-P-3515
Heat Tracing - Constant-Wattage Cable - Installation and Pre-Commissioning - SAIC-P-3516
Heat Tracing - Power-Limiting Cable - Installation and Pre-Commissioning - SAIC-P-3517
Heat Tracing - Tank Heating Pads - Installation and Pre-Commissioning - SAIC-P-3518
Heat Tracing - Instrument Housing - Installation and Pre-Commissioning - SAIC-P-3519
Heat Tracing - Pre-Traced Tubing - Installation and Pre-Commissioning - SAIC-P-3520
Heat Tracing - Power Connection Kit - Installation and Pre-Commissioning - SAIC-P-3521
Heat Tracing - Tee Kit - Installation and Pre-Commissioning - SAIC-P-3522
Heat Tracing - Spice Kit - Installation and Pre-Commissioning - SAIC-P-3523
Heat Tracing - End Seal and End-of-Circuit Kit - Installation and Pre-Commissioning - SAIC-P-3524
Heat Tracing - Control Panel - Installation and Pre-Commissioning - SAIC-P-3525
Heat Tracing - Thermostat, Ambient - Installation and Pre-Commissioning - SAIC-P-3526
Heat Tracing - Thermostat, Capillary Tube & Bulb - Installation and Pre-Commissioning - SAIC-P-3527
Heat Tracing - Thermostat, RTD - Installation and Pre-Commissioning - SAIC-P-3528
Heat Tracing - Contactor - Installation and Pre-Commissioning - SAIC-P-3529
HVAC System - Thermostat - Ambient, Bench Calibration - SATR-P-3403
HVAC System - Thermostat - Capillary Tube & Bulb, Bench Calibration - SATR-P-3404
HVAC System - Thermostat - RTD, Bench Calibration - SATR-P-3405
Heat Tracing - Cable Continuity and Insulation Resistance Testing (On Cable Reel) - SATR-P-3501
Heat Tracing - Tank Heating Pads Continuity and Insulation Resistance Testing - SATR-P-3502
Heat Tracing - Instrument Housing Continuity and Insulation Resistance Testing - SATR-P-3503
Heat Tracing - Cable Continuity and Insulation Resistance Testing (Installed Circuit) - SATR-P-3504
Heat Tracing - Circuit Energized Functional Testing - SATR-P-3505
10 High Voltage (35.001kV to 69kV) Cable : SATIP-P-104-10
High Voltage Cable - Material Receiving - SAIC-P-3216
High Voltage Cable Accessories - Material Receiving - SAIC-P-3217
High Voltage Cable - Installation and Pre-Commissioning - SAIC-P-3218
High Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3211
High Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3212
High Voltage Power Cable, Termination Torque Testing - SATR-P-3213
High Voltage Power Cable, High-Potential Withstand Testing - SATR-P-3214
11 Very High Voltage (Above 69kV) Cable : SATIP-P-104-11
Very High Voltage Cable - Material Receiving - SAIC-P-3220
Very High Voltage Cable Accessories - Material Receiving - SAIC-P-3221
Very High Voltage Cable - Installation and Pre-Commissioning - SAIC-P-3222
Very High Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3215
Very High Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3216
Very High Voltage Power Cable, Termination Torque Testing - SATR-P-3217
Very High Voltage Power Cable, Very High-Potential Withstand Testing - SATR-P-3218
12 Receptacles and Cord-Connected Equipment : SATIP-P-104-12
Receptacles & Cords - Pin-and-Sleeve Receptacle / Plug - Material Receiving - SAIC-P-3601
Receptacles & Cords - NEMA Receptacle / Plug - Material Receiving - SAIC-P-3602
Receptacles & Cords - Flexible Cord - Material Receiving - SAIC-P-3603
Receptacles & Cords - Cable Reels - Material Receiving - SAIC-P-3604
Receptacles & Cords - Festoon Systems - Material Receiving - SAIC-P-3605
Receptacles & Cords - Festoon Systems - Installation - SAIC-P-3606
Receptacles & Cords - Flexible Cord, Continuity and Insulation Resistance Testing (On cable reel) - SATR-P-3601
Receptacles & Cords - Flexible Cord, Continuity and Insulation Resistance Testing (Installed Cord, Cable, and Wire) - SATR-P-3602
Receptacles & Cords - Pin-and-Sleeve Receptacle / Plug - Installation, Functional and Polarity Testing - SATR-P-3603
Receptacles & Cords - NEMA Receptacle / Plug - Installaiton, Functional and Polarity Testing - SATR-P-3604
Receptacles & Cords - Cable Reels - Installation, Functional and Polarity Testing - SATR-P-3605
Receptacles & Cords - Festoon Systems - Installation, Functional and Polarity Testing - SATR-P-3606
13 Over-Head Transmission and Distribution Systems : SATIP-P-107-01
Overhead T&D Cable Termination and Splicing Special Work Procedure, Document Review - SAIC-P-3223
Overhead T&D Power Pole - Wood, Storage and Material Receiving - SAIC-P-3224
Overhead T&D Power Pole - Galvanized Steel, Storage and Material Receiving - SAIC-P-3226
Overhead T&D Power Structure - Galv. Lattice Steel, Storage and Material Receiving - SAIC-P-3228
Overhead T&D ACSR/AW Cable, Material Receiving - SAIC-P-3229
Overhead T&D Surge Arresters, Material Receiving - SAIC-P-3230
Overhead T&D Capacitor Banks, Material Receiving - SAIC-P-3231
Overhead T&D Metering Cabinet, Material Receiving - SAIC-P-3233
Overhead T&D Circuit Accessories, Material Receiving - SAIC-P-3234
Overhead T&D Power Pole, Installation - SAIC-P-3235
Overhead T&D Power Structure, Installation - SAIC-P-3236
Overhead T&D Equipment Installation and Pre-Commissioning - SAIC-P-3237
Overhead T&D Cable, Installation and Pre-Commissioning - SAIC-P-3238
Overhead T&D - Circuit Polarity, Continuity and Insulation Resistance Testing - SATR-P-3219
Overhead T&D - High-Potential Withstand Testing - SATR-P-3220
Overhead T&D - Cable Termination Torque Testing - SATR-P-3221
Overhead T&D - Surge Arresters, Functional Testing - SATR-P-3222
Overhead T&D - Capacitor Banks, Functional Testing - SATR-P-3223
Overhead T&D - Metering Cabinet, Functional Testing - SATR-P-3225
14 Grounding / Bonding : SATIP-P-111-01
General - Exothermic (Thermite) Welding Materials, Molds, & Tools - Material Receiving - SAIC-P-3018
GES - DCS/ESD/PLC/SCADA Grounding Installation - SAIC-P-3124
GEC/EGC - AC UPS System Grounding - SAIC-P-3125
GEC/EGC - DC System Grounding Installation - SAIC-P-3126
Grounding - GES - Ground Rods - Material Receiving - SAIC-P-3701
Electrical Grounding System - Final Inspection - SAIC-P-3702
Grounding - GES - Zinc and Magnesium Anode Electrodes - Material Receiving - SAIC-P-3704
Grounding - GES - Ground Electrode Cable - Material Receiving - SAIC-P-3705
Grounding - Bare Copper Ground Conductor - Material Receiving - SAIC-P-3706
Grounding - Bare Tinned Copper Ground Conductor - Material Receiving - SAIC-P-3707
Grounding - Hydraulic Compression Fittings and Tools - Material Receiving - SAIC-P-3708
Grounding and Bonding Accessories - Material Receiving - SAIC-P-3709
Grounding - Neutral Ground Resistor - Material Receiving - SAIC-P-3710
Grounding - GES - Copper, Copper-Clad Steel, Galvanized Steel Rod Installation - SAIC-P-3711
Grounding - GES - Zinc and Magnesium Anode Electrode Installation - SAIC-P-3712
Grounding - GES/GEC - Exothermic (Thermite) Welding Installation - SAIC-P-3713
Grounding - GES/GEC/EGC - Hydraulic Compression Connectors Installation - SAIC-P-3714
Grounding - GES - Concrete Embedded Copper Electrode Installation - SAIC-P-3715
Grounding - GES - Piping Electrode Installation - SAIC-P-3716
Grounding - GES - Structural Steel Electrode Installation - SAIC-P-3717
Grounding - GES - Copper Conductor Ground Ring Installation - SAIC-P-3718
Grounding - GES - Power Ground Electrode System (GES) Installation - SAIC-P-3719
Grounding - GES - Substation Grounding Installation - SAIC-P-3720
Grounding - GES - Cathodic Protection Grounding Installation - SAIC-P-3721
GES - Offshore Grounding Installation - SAIC-P-3722
GES - Telecommunications Grounding System Installation - SAIC-P-3723
GEC - High Resistance Grounding Installation - SAIC-P-3724
GEC - LV Dry Transformer Grounding Installation - SAIC-P-3725
GEC/EGC - Panelboard Grounding Installation - SAIC-P-3726
GEC/EGC - Switchgear / Controlgear Grounding Installation - SAIC-P-3727
GEC/EGC - DG Set System Grounding Installation - SAIC-P-3728
GEC/EGC - ATS / MTS System Grounding Installation - SAIC-P-3729
GEC/EGC - Pad-Mounted Transformer Grounding Installation - SAIC-P-3730
GEC/EGC - Power Transformer Grounding Installation - SAIC-P-3731
GEC/EGC - Variable Speed Drive Grounding Installation - SAIC-P-3732
EGC - Cable Tray Grounding / Bonding Installation - SAIC-P-3733
EGC - Conduit Grounding / Bonding Installation - SAIC-P-3734
EGC - Buried Cable Grounding / Bonding Installation - SAIC-P-3735
EGC - Ductbank Grounding / Bonding Installation - SAIC-P-3736
EGC - Electrical Eqpt. Grounding / Bonding Installation - SAIC-P-3737
EGC - Instrumentation Grounding / Bonding / Shielding Installation - SAIC-P-3738
EGC - Surge Arrestor Grounding / Bonding Installation - SAIC-P-3739
EGC - Process Eqpt. Grounding / Bonding Installation - SAIC-P-3740
EGC - Structural Steel Grounding / Bonding Installation - SAIC-P-3741
EGC - LV Cable Grounding / Bonding Installation - SAIC-P-3742
EGC - MV Cable Grounding / Bonding / Shielding Installation - SAIC-P-3743
EGC - Raised Floor Grounding / Bonding Installation - SAIC-P-3744
EGC - Offshore Grounding / Bonding Installation - SAIC-P-3745
EGC - Fence Grounding / Bonding Installation - SAIC-P-3746
EGC - Tank Grounding / Bonding Installation - SAIC-P-3747
EGC - Static Electricity Grounding / Bonding Installation - SAIC-P-3748
EGC - Isolated Grounding / Bonding Installation - SAIC-P-3749
Grounding - Soil Resistivity Test Report (Jobsite Final Soil) - SATR-P-3701
Grounding - GES - Electrode Resistance Test (IEEE 81) - SATR-P-3702
Grounding - GES - Electrode Resistance Test (Geonics) - SATR-P-3703
Grounding - EGC - Continuity to GES Testing - SATR-P-3704
Grounding - GEC - Neutral Ground Resistor Testing - SATR-P-3705
Grounding - EGC - Ground Termination Torque Testing - SATR-P-3706
15 Lighting Protection Systems : SATIP-P-111-02
Lightning Protection Air Terminals Material Receiving - SAIC-P-3750
Lightning Protection Ground Terminals Material Receiving - SAIC-P-3751
Lightning Protection Cable Material Receiving - SAIC-P-3752
Lightning Protection Accessories Material Receiving - SAIC-P-3753
Lightning Protection Air Terminals Installation - SAIC-P-3754
Lightning Protection Ground Terminals Installation - SAIC-P-3755
Lightning Protection Loop / Down / Bonding Conductor Installation - SAIC-P-3756
16 LV Induction Motors : SATIP-P-113-01
LV SCIM - Motor Storage, Handling, and Preservation - SAIC-P-3407
LV SCIM - Explosion-Proof Motor Material Receiving - SAIC-P-3408
LV SCIM - Severe Duty TE Motor Material Receiving - SAIC-P-3409
LV SCIM - API Air-Cooled H/E Fan Motor Material Receiving - SAIC-P-3410
LV SCIM - Non-Industrial Facilities Motor Material Receiving - SAIC-P-3411
LV SCIM - Squirrel-Cage Induction Motor Installation and Pre-Commissioning - SAIC-P-3413
LV SCIM - Motor Storage - Space Heater Insulation Resistance and Functional Testing - SATR-P-3406
LV SCIM - Motor Insulation Resistance and Functional Testing - SATR-P-3407
17 M.V. Induction Motors (Nameplate Voltage: 4kV, 6.6kV & 13.2kV) : SATIP-P-113-02
MV Motor - Storage, Handling, and Preservation - SAIC-P-3414
MV Motor - Form Wound Squirrel Cage Induction Motor (SCIM) Material Receiving - SAIC-P-3415
MV Motor - Form Wound Synchronous Motor Material Receiving - SAIC-P-3416
MV Motor - Non-industrial Facilities Motor Material Receiving - SAIC-P-3417
MV Motor - Motor Accessories Material Receiving - SAIC-P-3418
MV Motor - Motor Installation and Pre-Commissioning - SAIC-P-3419
MV Motor - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3408
MV Motor - Form Wound SCIM Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3409
MV Motor - Form Wound Synchronous Motor Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3410
MV Motor - Non-industrial Facilities Motor Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3411
18 Diesel-Generator Set : SATIP-P-113-03
DG Set - Storage, Handling, and Preservation - SAIC-P-3420
DG Set - Engine and Synchronous Generator Material Receiving - SAIC-P-3421
DG Set - GCB, Voltage Regulator, Enclosure, Load Test Set, and DG Accessories Material Receiving - SAIC-P-3422
DG Set - Installation and Pre-Commissioning - SAIC-P-3423
DG Set - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3412
DG Set - Form Wound Synchronous Generator Insulation Resistance and Functional Testing - SATR-P-3413
Download SATIP Index xlsx file
19 Cranes, Hoists and Elevators : SATIP-P-113-04
Cranes, Hoists, Elevators - Specialty Equipment and Accessories Material Receiving - SAIC-P-3424
Cranes, Hoists, Elevators - Installation and Pre-Commissioning - SAIC-P-3425
Crane Insulation Resistance and Functional Testing - SATR-P-3414
Hoist Insulation Resistance and Functional Testing - SATR-P-3415
Elevator Insulation Resistance and Functional Testing - SATR-P-3416
20 Annunciator Metering and Protection Relaying Cabinets : SATIP-P-114-01
Protection & Metering - Annunciator Panel Material Receiving - SAIC-P-3801
Protection & Metering - Metering Cabinet Material Receiving - SAIC-P-3802
Protection & Metering - Relay Cabinet Material Receiving - SAIC-P-3803
Protection & Metering - Current Transformer Material Receiving - SAIC-P-3804
Protection & Metering - Potential Transformer Material Receiving - SAIC-P-3805
Protection & Metering - Protection Relay Material Receiving - SAIC-P-3806
Protection & Metering - Electric Meter / Recorder Material Receiving - SAIC-P-3807
Protection & Metering - Accessories Material Receiving - SAIC-P-3808
Protection & Metering - Equipment Installation and Pre-Commissioning - SAIC-P-3809
Protection & Metering - CT and PT Installation and Pre-Commissioning - SAIC-P-3810
Protection & Metering - Relay Installation and Pre-Commissioning - SAIC-P-3811
Protection & Metering - Meter / Recorder Installation and Pre-Commissioning - SAIC-P-3812
Protection & Metering - Relay Calibration, Setting, and Functional Testing - SATR-P-3801
Protection & Metering - Meter / Recorder Calibration, Setting, and Functional Testing - SATR-P-3802
Protection & Metering - Annunciator Pre-energization and Functional Testing - SATR-P-3803
Protection & Metering - CT Pre-energization and Functional Testing - SATR-P-3804
Protection & Metering - PT Pre-energization and Functional Testing - SATR-P-3805
21 MV Switchgear : SATIP-P-116-01
MV Switchgear - Metal-Clad Switchgear (Indoor/Outdoor) Material Receiving - SAIC-P-3813
MV Switchgear - SF6 Switchgear (Outdoor) Material Receiving - SAIC-P-3814
MV Switchgear - Manual SF6 Circuit Breaker Material Receiving - SAIC-P-3815
MV Switchgear - Vacuum Circuit Breaker (Motor Load) Material Receiving - SAIC-P-3816
MV Switchgear - Vacuum Circuit Breaker (Feeder Load) Material Receiving - SAIC-P-3817
MV Switchgear - Accessories Material Receiving - SAIC-P-3818
MV Switchgear - Metal-Clad Switchgear Installation and Pre-Commissioning - SAIC-P-3819
MV Switchgear - SF6 Switchgear Installation and Pre-Commissioning - SAIC-P-3820
MV Switchgear - MV Manual SF6 Circuit Breaker Pre-Commissioning - SAIC-P-3821
MV Switchgear - MV Vacuum Circuit Breaker - Motor Load Pre-Commissioning - SAIC-P-3822
MV Switchgear - MV Vacuum Circuit Breaker - Feeder Pre-Commissioning - SAIC-P-3823
MV Switchgear / Controlgear - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3806
MV Switchgear - Metal-Clad Switchgear Pre-Energized and Functional Testing - SATR-P-3807
MV Switchgear - SF6 Switchgear, Pre-Energized and Functional Testing - SATR-P-3808
MV Switchgear - MV Manual SF6 Circuit Breaker Calibration, Setting, and Functional Testing - SATR-P-3809
MV Switchgear - MV Vacuum Circuit Breaker - Motor Load Calibration, Setting, and Functional Testing - SATR-P-3810
MV Switchgear - MV Vacuum Circuit Breaker - Feeder Calibration, Setting, and Functional Testing - SATR-P-3811
22 MV Controlgear : SATIP-P-116-02
MV Controlgear - Metal-Enclosed Equipment (Indoor/Outdoor) Material Receiving - SAIC-P-3824
MV Controlgear - Power Circuit Breaker Material Receiving - SAIC-P-3825
MV Controlgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3829
MV Controlgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3830
MV Controlgear - Fused Motor Controller Pre-Commissioning - SAIC-P-3831
MV Controlgear - Fused Switching Assembly Pre-Commissioning - SAIC-P-3832
MV Controlgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3812
MV Controlgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3813
MV Controlgear - Fused Motor Controller - Motor Load Calibration, Setting, and Functional Testing - SATR-P-3814
MV Controlgear - Fused Switching Assembly - Feeder Load Calibration, Setting, and Functional Testing - SATR-P-3815
23 LV Switchgear and Switchboards : SATIP-P-116-03
LV Switchgear - Indoor/Outdoor Equipment Material Receiving - SAIC-P-3833
LV Switchboard - Material Receiving - SAIC-P-3834
LV Switchgear - Power Circuit Breaker Material Receiving - SAIC-P-3835
LV Switchgear / Switchboard - Molded Case Breaker Material Receiving - SAIC-P-3836
LV Switchgear / Switchboard - Accessories Material Receiving - SAIC-P-3837
LV Switchgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3838
LV Switchgear / Switchboard - Molded Case Breaker Pre-Commissioning - SAIC-P-3839
LV Switchgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3840
LV Switchboard - Installation and Pre-Commissioning - SAIC-P-3841
LV Switchgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3816
LV Switchgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3817
LV Switchgear / Switchboard - Molded Case Circuit Breaker Calibration, Setting, and Functional Testing - SATR-P-3818
24 LV Controlgear TIP : SATIP-P-116-04
LV Controlgear - Metal-Enclosed Equipment (Indoor/Outdoor) Material Receiving - SAIC-P-3842
LV Controlgear - Power Circuit Breaker Material Receiving - SAIC-P-3843
LV Controlgear - Full Voltage Motor Controller Material Receiving - SAIC-P-3844
LV Controlgear - Reduced Voltage Motor Controller Material Receiving - SAIC-P-3845
LV Controlgear - Feeder Contactor Material Receiving - SAIC-P-3846
LV Controlgear - ATS / MTS Material Receiving - SAIC-P-3847
LV Controlgear - Accessories Material Receiving - SAIC-P-3848
LV Controlgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3849
LV Controlgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3850
LV Controlgear - Full Voltage Motor Controller Pre-Commissioning - SAIC-P-3851
LV Controlgear - Reduced Voltage Motor Controller Pre-Commissioning - SAIC-P-3852
LV Controlgear - Feeder Contactor Pre-Commissioning - SAIC-P-3853
LV Controlgear - ATS / MTS Pre-Commissioning - SAIC-P-3854
LV Controlgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3819
LV Controlgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3820
LV Controlgear - Full Voltage Motor Controller Calibration, Setting, and Functional Testing - SATR-P-3821
LV Controlgear - Reduced Voltage Motor Controller Calibration, Setting, and Functional Testing - SATR-P-3822
LV Controlgear - Feeder Contactor Calibration, Setting, and Functional Testing - SATR-P-3823
LV Controlgear - ATS / MTS Calibration, Setting, and Functional Testing - SATR-P-3824
25 Switchracks and Distribution Racks : SATIP-P-116-05
Switchrack Material Receiving - SAIC-P-3855
Switchrack Pre-Commissioning - SAIC-P-3857
26 Fire Water Pump / Motor / Controller : SATIP-P-116-06
LV SCIM for Fire Water Pump Service Material Receiving - SAIC-P-3454
LV Severe Duty TE SCIM Material Receiving - SAIC-P-3455
LV SCIM for Non-Industrial Facilities (Jockey Pump Service) Material Receiving - SAIC-P-3456
LV Motor Controller for Fire Service Material Receiving - SAIC-P-3457
Fire / Jockey Pump Motors & Controller Installation and Pre-Commissioning - SAIC-P-3458
Fire / Jockey Pump Motors & Controller Calibration, Settings, and Testing (Installed Motor) - SATR-P-3417
27 LV Panelboards : SATIP-P-116-07
LV Panelboard-Industrial Outdoor Panelboard(≤400A)Material Receiving - SAIC-P-3859
LV Panelboard - Non-Industrial Panelboard Material Receiving - SAIC-P-3860
LV Panelboard - Industrial Explosion-Proof Panelboard (≤400A) Material Receiving - SAIC-P-3862
LV Panelboard - Non-Hazardous AC/DC Panelboard Installation and Pre-Commissioning - SAIC-P-3867
LV Panelboard - Explosion-Proof Panelboard Installation and Pre-Commissioning - SAIC-P-3869
LV Panelboard - Pre-Energized and Functional Testing - SATR-P-3825
28 MV (max 35kV) Non-seg Busduct : SATIP-P-116-08
MV Non-Seg Busduct Material Receiving - SAIC-P-3239
MV Non-Seg Busduct Installation and Pre-Commissioning - SAIC-P-3241
MV Non-Seg Busduct Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3242
MV Non-Seg Busduct High-Potential Withstand Testing - SATR-P-3227
MV Non-Seg Busduct Torque Testing - SATR-P-3228
MV Non-Seg Busduct Continuity, Insulation, and Space Heater Functionality Testing - SATR-P-3229
29 MV (max. 15kV) Cablebus) : SATIP-P-116-10
MV Cablebus Framework Material Receiving - SAIC-P-3247
MV Cablebus Conductor Material Receiving - SAIC-P-3248
MV Cablebus Accessories Material Receiving - SAIC-P-3249
MV Cablebus Installation and Pre-Commissioning - SAIC-P-3250
MV Cablebus Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3251
MV Cablebus Continuity and Insulation Resistance Testing - SATR-P-3233
MV Cablebus Torque Testing - SATR-P-3234
MV Cablebus High-Potential Withstand Testing - SATR-P-3235
30 LV Non-seg Busduct : SATIP-P-116-11
LV Non-Seg Busduct Material Receiving - SAIC-P-3252
LV Non-Seg Busduct Accessories Material Receiving - SAIC-P-3253
LV Non-Seg Busduct Installation and Pre-Commissioning - SAIC-P-3254
LV Non-Seg Busduct Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3255
LV Non-Seg Busduct Torque Testing - SATR-P-3236
LV Non-Seg Busduct Continuity, Insulation, and Space Heater Functionality Testing - SATR-P-3237
31 LV Cablebus : SATIP-P-116-12
LV Cablebus Framework Material Receiving - SAIC-P-3256
LV Cablebus Conductor Material Receiving - SAIC-P-3257
LV Cablebus Accessories Material Receiving - SAIC-P-3258
LV Cablebus Installation and Pre-Commissioning - SAIC-P-3259
LV Cablebus Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3260
LV Cablebus Continuity and Insulation Resistance Testing - SATR-P-3238
LV Cablebus Torque Testing - SATR-P-3239
Download SATIP Index xlsx file
32 VSD Equipment : SATIP-P-116-13
VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Material Receiving - SAIC-P-3426
VSD - Liquid Cooled LV AFD Material Receiving - SAIC-P-3427
VSD - Air Cooled MV AFD Material Receiving - SAIC-P-3428
VSD - Liquid Cooled MV AFD Material Receiving - SAIC-P-3429
VSD - Source Isolation Transformer Material Receiving - SAIC-P-3430
VSD - Induction Motors Material Receiving - SAIC-P-3431
VSD - DC Link Reactor Material Receiving - SAIC-P-3432
VSD - Cooling Liquid Pumps Material Receiving - SAIC-P-3433
VSD - Cooing Fans Material Receiving - SAIC-P-3434
VSD - Cooling Liquid Piping Material Receiving - SAIC-P-3435
VSD - Cooling System Valves Material Receiving - SAIC-P-3436
VSD - Painting / Coating / Insulation Material Receiving - SAIC-P-3437
VSD - Cooling System Heat Exchanger Material Receiving - SAIC-P-3438
VSD - Cooling Control System Material Receiving - SAIC-P-3439
VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Material Receiving - SAIC-P-3440
VSD - Liquid Cooled LV AFD Installation and Pre-Commissioning - SAIC-P-3441
VSD - Air Cooled MV AFD Installation and Pre-Commissioning - SAIC-P-3442
VSD - Liquid Cooled MV AFD Installation and Pre-Commissioning - SAIC-P-3443
VSD - Source Isolation Transformer Installation and Pre-Commissioning - SAIC-P-3444
VSD - Induction Motors Installation and Pre-Commissioning - SAIC-P-3445
VSD - DC Link Reactor Installation and Pre-Commissioning - SAIC-P-3446
VSD - Cooling Liquid Pumps Installation and Pre-Commissioning - SAIC-P-3447
VSD - Cooing Fans Installation and Pre-Commissioning - SAIC-P-3448
VSD - Cooling Liquid Piping Installation and Pre-Commissioning - SAIC-P-3449
VSD - Cooling System Valves Installation and Pre-Commissioning - SAIC-P-3450
VSD - Painting / Coating / Insulation Installation and Pre-Commissioning - SAIC-P-3451
VSD - Cooling System Heat Exchanger Installation and Pre-Commissioning - SAIC-P-3452
VSD - Cooling Control System Installation and Pre-Commissioning - SAIC-P-3453
VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Pre-Energizing and Functional Testing - SATR-P-3418
VSD - Liquid Cooled LV AFD Pre-Energizing and Functional Testing - SATR-P-3419
VSD - Air Cooled MV AFD Pre-Energizing and Functional Testing - SATR-P-3420
VSD - Liquid Cooled MV AFD Pre-Energizing and Functional Testing - SATR-P-3421
VSD - Source Isolation Transformer Pre-Energizing and Functional Testing - SATR-P-3422
VSD - Induction Motors Pre-Energizing and Functional Testing - SATR-P-3423
VSD - DC Link Reactor Pre-Energizing and Functional Testing - SATR-P-3424
VSD - Cooling Liquid Pumps Pre-Energizing and Functional Testing - SATR-P-3425
VSD - Cooing Fans Pre-Energizing and Functional Testing - SATR-P-3426
VSD - Cooling Liquid Piping Pre-Energizing and Functional Testing - SATR-P-3427
VSD - Cooling System Valves Pre-Energizing and Functional Testing - SATR-P-3428
VSD - Painting / Coating / Insulation Pre-Energizing and Functional Testing - SATR-P-3429
VSD - Cooling System Heat Exchanger Pre-Energizing and Functional Testing - SATR-P-3430
VSD - Cooling Control System Pre-Energizing and Functional Testing - SATR-P-3431
33 HV Switchyard : SATIP-P-119-01
Switchyard - ACSR Cable and Accessories Storage, Handling, and Preservation - SAIC-P-3901
Switchyard - HV Equipment Storage, Handling, and Preservation - SAIC-P-3902
Switchyard - Seamless Aluminum Bus Pipe and Accessories Material Receiving and Storage - SAIC-P-3903
Switchyard - Aluminum Conductor Steel Reinforced (ACSR) Cable and Accessories Material Receiving - SAIC-P-3904
Switchyard - HV SF6 C/B's and Switchgear Material Receiving - SAIC-P-3905
Switchyard - HV Post Insulators Material Receiving - SAIC-P-3906
Switchyard - HV Surge Arrestors and Capacitors Material Receiving - SAIC-P-3907
Switchyard - HV Disconnect Switches (Motor-operated and manual) Material Receiving - SAIC-P-3908
Switchyard - HV Metering and Protection CT's & PT's Material Receiving - SAIC-P-3909
Switchyard - HV SF6 C/B's and Switchgear Installation and Pre-Commissioning - SAIC-P-3910
Switchyard - HV Post Insulators Installation and Pre-Commissioning - SAIC-P-3911
Switchyard - HV Surge Arrestors and Capacitors Installation and Pre-Commissioning - SAIC-P-3912
Switchyard - HV Disconnect Switches (Motor-operated and manual) Installation and Pre-Commissioning - SAIC-P-3913
Switchyard - HV Metering and Protection CT's & PT's Installation and Pre-Commissioning - SAIC-P-3914
Switchyard - Seamless Aluminum Bus Pipe and Accessories Installation and Pre-Commissioning - SAIC-P-3915
Switchyard - Aluminum Conductor Steel Reinforced (ACSR) Cable and Accessories Installation and Pre-Commissioning - SAIC-P-3916
Switchyard - HV Mechanical Termination Torque Testing - SATR-P-3901
Switchyard - HV Conductor (Pipe and ACSR) Continuity and Conductivity Testing - SATR-P-3902
Switchyard - HV Ground Electrode System Continuity and Resistance Testing - SATR-P-3903
Switchyard - HV Conductor (Pipe and ACSR) High-Potential Withstand Testing - SATR-P-3904
Switchyard - HV SF6 C/B's and Switchgear Pre-Energization and Functional Testing - SATR-P-3905
Switchyard - HV Disconnect Switches (Motor-operated and manual) Pre-Energization and Functional Testing - SATR-P-3906
34 Dry Type Transformers : SATIP-P-121-01
Dry Transformer - LV Non-Vented Xfmr (≤500 kVA, LV Pri) Material Receiving and Storage - SAIC-P-3918
Dry Transformer - MV Xfmr (MV or ≥501 kVA) Material Receiving and Storage - SAIC-P-3919
Dry Transformer - LV Xfmr (≤500 kVA, LV Pri) Assembly, Installation and Pre-Commissioning - SAIC-P-3920
Dry Transformer - MV Xfmr (MV or ≥501 kVA) Assembly, Installation and Pre-Commissioning - SAIC-P-3921
Dry Transformer - LV Xfmr (≤500 kVA, LV Pri) Pre-Commissioning and Functional Testing - SATR-P-3907
Dry Transformer - MV Xfmr (MV or ≥501 kVA) Pre-Commissioning and Functional Testing - SATR-P-3908
35 Power Transformers : SATIP-P-121-02
Power Transformer - Storage, Handling, and Preservation - SAIC-P-3922
Power Transformer - Material Receiving - SAIC-P-3923
Power Transformer Accessories - Material Receiving - SAIC-P-3924
Power Transformer - Installation, Assembly, and Filling - SAIC-P-3925
Power Transformer - Pre-Commissioning and Energization - SAIC-P-3926
Power Transformer Pressure - Storage, Handling, and Installaiton - SATR-P-3909
Power Transformer Vibration Event - Storage, Handling, and Installation - SATR-P-3910
Power Transformer Tank - Jobsite Acceptance Test - SATR-P-3911
Power Transformer - Jobsite Testing - SATR-P-3912
36 Overhead Transformers : SATIP-P-121-03
Overhead Transformer - Material Receiving - SAIC-P-3927
Overhead Transformer Accessories - Material Receiving - SAIC-P-3928
Overhead Transformer - Installation, Assembly, and Filling - SAIC-P-3929
Overhead Transformer - Pre-Commissioning and Energization - SAIC-P-3930
Overhead Transformer - Jobsite Acceptance Test - SATR-P-3913
Overhead Transformer - Jobsite Testing - SATR-P-3914
37 Pad Mounted Transformers : SATIP-P-121-04
Self-Cooled Pad-Mounted MV Transformer - Material Receiving - SAIC-P-3931
Self-Cooled Pad-Mounted MV Transformer Accessories - Material Receiving - SAIC-P-3932
Self-Cooled Pad-Mounted MV Transformer - Installation, Assembly, and Filling - SAIC-P-3933
Self-Cooled Pad-Mounted MV Transformer - Pre-Commissioning and Energization - SAIC-P-3934
Self-Cooled Pad-Mounted MV Transformer - Jobsite Acceptance Test - SATR-P-3915
Self-Cooled Pad-Mounted MV Transformer - Jobsite Testing - SATR-P-3916
38 Light Fixtures and Lighting Systems : SATIP-P-123-01
Fluorescent Light Fixtures - Material Receiving - SAIC-P-3610
HID Light Fixtures - Material Receiving - SAIC-P-3611
Emergency Light Fixtures - Material Receiving - SAIC-P-3612
Incandescent Light Fixtures - Material Receiving - SAIC-P-3613
12V High Intensity Incandescent Fixtures - Material Receiving - SAIC-P-3614
Aviation / Obstruction Light Fixtures - Material Receiving - SAIC-P-3615
Lighting Accessories - Material Receiving - SAIC-P-3616
Light Pole Assembly and Installation - SAIC-P-3617
Hung Ceiling Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3618
Surface Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3619
Flush Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3620
HID High-bay Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3621
HID Low-bay Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3622
Lighting Control System - Installation and Pre-Commissioning - SAIC-P-3623
Pole-Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3624
Security Light Fixtures (Fence, Area, and Checkpoint Ltg.) - Assembly, Installation, and Pre-Commissioning - SAIC-P-3625
Aviation / Obstruction Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3626
Offshore Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3627
Area & Street Lighting (point to point) - Illumination Level Testing - SATR-P-3610
Interior Lighting (zone cavity) - Illumination Level Testing - SATR-P-3611
Sports Lighting - Illumination Level Testing - SATR-P-3612
Security Lighting (Fence, Area, and Checkpoint Ltg.) - Illumination Level Testing - SATR-P-3613
Aviation / Obstruction Light Fixtures - Illumination Level Testing - SATR-P-3614
Offshore Lighting - Illumination Level Testing - SATR-P-3615
39 Factory Assembled (Packaged) Auxiliary Electrical Equipment : SATIP-P-515-01
General Mechanical Equipment Skid for Zone or Div 1 - Material Receiving - SAIC-P-3019
General Mechanical Equipment Skid for Zone or Div 2 - Material Receiving - SAIC-P-3020
General Mechanical Equipment Skid for Non-Hazardous Locations - Material Receiving - SAIC-P-3021
General Mechanical Equipment Skid for Corrosive locations - Material Receiving - SAIC-P-3022
General Electrical Workspace Clearances - SAIC-P-3023
40 Off-Plot Galvanic Cathodic Protection : SATIP-X-400-01
Exothermic Welding Tools & Materials - Material Receiving - SAIC-X-3001
CP Accessories - Material Receiving - SAIC-X-3002
Exothermic Welding - SAIC-X-3003
Galvanic Anodes for CP (Aluminum, Magnesium, and Zinc Anodes) - Material Receiving - SAIC-X-3101
Galvanic CP Test Stations / Junction Boxes - Material Receiving - SAIC-X-3102
Galvanic CP Anode Installation and Pre-Commissioning - SAIC-X-3103
Galvanic CP Test Station Installation and Pre-Commissioning - SAIC-X-3104
Galvanic CP Cable Installation, Termination, and Identification - SAIC-X-3105
Galvanic CP Testing - SATR-X-3101
Galvanic CP Anode Installation and Pre-Commissioning - SATR-X-3103
41 Off-Plot Impressed Current Cathodic Protection : SATIP-X-400-02
DC Cable Holiday Testing - SATR-X-3201
Impressed Current CP Testing - SATR-X-3202
Plant Potential Survey Testing - SATR-X-3203
External Tank Bottom Testing - SATR-X-3204
Internal Tank Potential Testing - SATR-X-3205
42 On-plot Galvanic Cathodic Protection : SATIP-X-600-02
CP Rectifier - Material Receiving - SAIC-X-3201
Impressed Current Anode - Material Receiving - SAIC-X-3202
Impressed Current CP Cable - Material Receiving - SAIC-X-3203
DC Rectifier Installation and Pre-Commissioning - SAIC-X-3204
Impressed Current CP Anode Installation and Pre-Commissioning - SAIC-X-3205
Impressed Current CP Deep Anode Bed Installation and Pre-Commissioning - SAIC-X-3206
Impressed Current CP Cable Installation, Termination, and Identification - SAIC-X-3207