QC Notes Electrical Inspector Part-3
Q81. | Bonding box test station are required grounding? | |
Answer : | yes | |
Q82. | LV cable mini temp rating? | |
Answer : | 85 degree centigrade | |
Q83. | Mini Conduit size? | |
Answer : | 3/4 inch | |
Q84. | Snap switches rated 20A or less directly connected to ---- conductor shall be listed and marked CO/ALR. | |
Answer : | 0 | |
Q85. | What is Minimum rating of power panel? | |
Answer : | 400 Ampere | |
Q86. | Type MC cable shall be supported and secured by staples; cable ties listed and identified for securement and support; -------, hangers, or similar fittings; or other approvedbn means designed and installed so as not to damage the cable. | |
Answer : | 2- straps | |
Q87. | Purpose of solo Run test? | |
Answer : | 0 | |
Q88. | Coordination and coordinated as used in this section do not cover the …...range of overcurrent conditions? | |
Answer : | 0 | |
Q89. | What is the ambient temp of indoor Electrical equipment? | |
Answer : | 0 | |
Q90. | The elevation of the bottom of the lowest interior cable tray shall be a | |
Answer : | 4.6 meter | |
Q91. | Drill stem and test anode resistance test after how many metter was taken ? | |
Answer : | 0 | |
Q92. | Spring pressure type twist-on connectors, and pressure set screw connectors | |
Answer : | 3-lighting and receptacle circuits in non-hazardous locations, | |
Q93. | In Galvanic Area which type of Rod shall be used.? | |
Answer : | galvanized | |
Q94. | When normal light gone and required emergency light which switch tranfer the system on emergency power ? | |
Answer : | c) emergency transfer switch | |
Q95. | Who is the responcible of health care facility ? | |
Answer : | | |
Q96. | What we call when water is filled out in a container before it spills out? | |
Answer : | | |
Q97. | A vessel that hold plate electrolyte and other element of single unit called? | |
Answer : | sttorage battery | |
Q98. | When conduit is used in damp and wet location inside of the conduit what we call? | |
Answer : | wet | |
Q99. | which conductor shall be used for ground grid to grond rod? | |
Answer : | stranded bare copper conductor | |
Q100. | sprinkler are permitted at 6.5ft in switchgear room? 1-Required some jurisdiction, 2- leakage of switchgear area. | |
Answer : | | |
Q101. | Fire pump Wiring Method? | |
Answer : | 1- NM Cable | |
Q102. | The may cause the condition to go to alarm, allowing corrective action or an orderly shutdown, thereby minimizing personnel hazard and equipment damage. | |
Answer : | Monitoring System | |
Q103. | The conductors supplying the primary of a transformer have an ampacity at least the rating of the over‐ current device protecting the feeder conductors. | |
Answer : | One-Third | |
Q104. | Circuit breakers used as switches in 120-volt and 277-volt fluorescent lighting circuits shall be listed and shall be marked | |
Answer : | SWD OR HID | |
Q105. | Where the transformer supplying the service is located outside the building, at least additional grounding connection | |
Answer : | ONE | |
Q106. | If practicable, rod, pipe, and plate electrodes shall be embedded below permanent moisture level. | |
Answer : | FALSE | |
Q107. | The paralleling efficiency of rods is by spacing them twice the length of the longest rod | |
Answer : | INCREASED | |
Q108. | The ceiling support system shall be permitted to support branch-circuit wiring and associated equipment | |
Answer : | TRUE | |
Q109. | Round boxes shall be used where conduits or connectors requiring the use of locknuts or bushings are to be connected to the side of the box. | |
Answer : | FALSE | |
Q110. | The weight supported by any single conduit does not exceed | |
Answer : | 9 KG | |
Q111. | In pull boxes or junction boxes having any dimension over, all conductors shall be cabled or racked up in an approved manner. | |
Answer : | 1.8 m (6 ft) | |
Q112. | Switches and circuit breakers installed adjacent to motors, appliances, or other equipment that they supply | |
Answer : | 1.8 m (6 ft) | |
Q113. | Branch-circuit conductors supplying a single motor-compressor shall have an ampacity not less than 125% of | |
Answer : | TRUE | |
Q114. | A conduit seal shall be required in each conduit run leaving a Class I, Division 2 location. | |
Answer : | 3.05 m (10 ft) | |
Q115. | The ground resistance of made electrodes (ground rods and/or ground grid) used for system grounding shall not exceed ____ ohm for system under 600V | |
Answer : | c) 5 | |
Q116. | Which NEC Article related with HDPE. | |
Answer : | NEC-353 | |
Q117. | Grounding and bonding article? | |
Answer : | 250 | |
Q118. | At pipeline transitions through asphalt or concrete, provide around the transition, | |
Answer : | 30 cm of unpaved soil | |
Q119. | RMC used for Swimming pool installation | |
Answer : | Red brass | |
Q120. | Fire Pump shall be installed 18 inch above ground. | |
Answer : | TRUE/FALSE - 12" |
- ARAMCO :: CBT QA/QC – Instrumentation Inspector Qualification Guideline
- Saudi Aramco Cbt Exam Questions and Answers
- CBT EXAM E-BOOKS
- QA/QC ELECTRICL Inspector Question & Answer Handbooks
- QA/QC E-books Category
- Electrical QC Notes of Saudi Aramco Qualification Guideline
- QAQC Questionnaires CONDUIT; CABLE TRAY; ENCLOSURES;
- INSTRUMENTATION QUESTIONAIRE: QAQC CBT ARAMCO
- Part-1 QC Notes Electrical Inspector Part-1 :: ARAMCO CBT
- Part-2 QC Notes Electrical Inspector