loading...
We provide you the latest 200 quiz questions and answers for engineers and technicians of instrumentation and control professions.
Instrumentation and Control
Find the sample 30 questions from the instrumentation and control quiz. Click on the below start button to get complete 200 questions with answers.
Question 1:
Which is not an applicable method to detect the presence of flammable gas
A) Point Type IR Detectors
B) Electrochemical sensors
C) Catalytic sensors
D) Open Path IR Detectors
B) Electrochemical sensors
C) Catalytic sensors
D) Open Path IR Detectors
Question 2:
Following standard defines Procedure Automation for Continuous Process Operations
A) ISA 18.2
B) None of the answers
C) ISA 106
D) ISA 95
B) None of the answers
C) ISA 106
D) ISA 95
Question 3:
Which of the following valve types would be suitable for controlling the flow of a slurry?
A) Double-seated globe
B) Butterfly
C) Diaphragm
D) Knife edge gate
B) Butterfly
C) Diaphragm
D) Knife edge gate
Question 4:
List the device that is not a common output transducer for an electronic pressure transmitter
A) capacitance
B) LVDT
C) strain gage
D) flapper-nozzle
B) LVDT
C) strain gage
D) flapper-nozzle
Question 5:
Following statement is true when exchanging Digital O/P signal from DCS to package PLC
A) DCS Relay's potential free contact shall be wired to Package PLC's DI Channel
B) Package PLC DI channel shall provide interrogation voltage to DCS Relay contact
C) DCS shall have relay output
D) All of the statements are true
B) Package PLC DI channel shall provide interrogation voltage to DCS Relay contact
C) DCS shall have relay output
D) All of the statements are true
Question 6:
Select the false statement for analog type input/output
A) When field device has active output it means that control system should not give voltage for loop powering
B) Loop powered means voltage supplied by Control System
C) Control system output is configured as passive type when it gives output to another PLC
D) Field device output is passive when connected for loop powered by Control System
B) Loop powered means voltage supplied by Control System
C) Control system output is configured as passive type when it gives output to another PLC
D) Field device output is passive when connected for loop powered by Control System
Question 7:
When performing a zero-based calibration on a D/P transmitter, the low pressure port of the transmitter:
A) should be closed
B) should be connected to a 2.04 "Hg vacuum source
C) should be connected to the high pressure air supply
D) should be vented to the atmosphere
B) should be connected to a 2.04 "Hg vacuum source
C) should be connected to the high pressure air supply
D) should be vented to the atmosphere
Question 8:
The purpose of indicating Control Valve Air Failure Action in I/O Database is
A) to decide controller output direction (0%=Valve Close; 100%=Valve Open)
B) to decide controller action (Direct / reverse)
C) It is irrelevant for DCS vendor
D) to decide input (PV) direction to controller
B) to decide controller action (Direct / reverse)
C) It is irrelevant for DCS vendor
D) to decide input (PV) direction to controller
Question 9:
Following instrument is used to measure shaft phase angle and give signal per rotation
A) Proximeters
B) Keyphaser
C) Accelometers
D) Tacometer
B) Keyphaser
C) Accelometers
D) Tacometer
Question 10:
Which configuration is the safest (i.e., the one most likely to respond to a true demand)?
A) 1oo1
B) None of the answers
C) 2oo2
D) 1oo2
A) 1oo1
B) None of the answers
C) 2oo2
D) 1oo2
Question 11:
Interface level transmitter output is
A) 12mA when tank is filled 50% physically
B) 4 mA when tank is fully filled with heavier fluid
C) 20 mA when tank is fully filled with lighter fluid
D) 20 mA when tank is fully filled with heavier fluid
B) 4 mA when tank is fully filled with heavier fluid
C) 20 mA when tank is fully filled with lighter fluid
D) 20 mA when tank is fully filled with heavier fluid
Question 12:
Following standard is referred for wedge meter
A) It is normally as per manufacturer standard
B) ISO 5167 Part 5: 2016
C) ISO 5167 Part 6: 2019
D) There no standard exists
B) ISO 5167 Part 5: 2016
C) ISO 5167 Part 6: 2019
D) There no standard exists
Question 13:
According to IEC 681131, a PLC is programmed in
A) Ladder logic
B) SFC
C) Any of the answers
D) Function blocks
B) SFC
C) Any of the answers
D) Function blocks
Question 14:
PROFIBUS-DP is different from PA because:
A) It has a different message format.
B) The difference is just marketing fluff
C) It uses a different media access method
D) It uses a different cable type and signaling method
B) The difference is just marketing fluff
C) It uses a different media access method
D) It uses a different cable type and signaling method
Question 15:
Which of the following is often not included in an alarm system audit?
A) Alarm system requirement specification.
B) Alarm system performance metrics.
C) Operator interviews.
D) Out-of-service alarms.
B) Alarm system performance metrics.
C) Operator interviews.
D) Out-of-service alarms.
Question 16:
Which flowmeter is suitable for Low Reynolds number and high viscous service
A) Pitot
B) Orifice
C) Wedge
D) Venturi
B) Orifice
C) Wedge
D) Venturi
Question 17:
The process of securing a system by reducing its attack surface is known as
A) Threat Modeling
B) Whitelisting
C) System Hardening
D) Intrusion Detection
B) Whitelisting
C) System Hardening
D) Intrusion Detection
Question 18:
The following is not applicable term with respect to Modbus RTU Configuration
A) Baud Rate
B) OPC
C) Bit Reversal
D) Odd / Even Parity
B) OPC
C) Bit Reversal
D) Odd / Even Parity
Question 20:
All OPC Servers must present as a minimum which interface?
A) browser
B) application
C) custom
D) unique
B) application
C) custom
D) unique
Question 21:
The CV rating of a valve is used to
A) Calculate the flow thru a valve
B) Calculate the Δp across a valve
C) All of the answers
D) Calculate the % valve open
B) Calculate the Δp across a valve
C) All of the answers
D) Calculate the % valve open
Question 22:
Bypassing a Safety Instrumented Function may be required for:
A) Prevention of nuisance alarms
B) Keep from shutting down an effected operating area during upset conditions
C) Safety Instrumented Functions are not permitted to be bypassed under any circumstance
D) Maintenance, functional testing, and replacement
B) Keep from shutting down an effected operating area during upset conditions
C) Safety Instrumented Functions are not permitted to be bypassed under any circumstance
D) Maintenance, functional testing, and replacement
Question 23:
Valve flow characteristics can only be changed by:
A) Adding upstream restrictors
B) Changing the valve
C) Changing the valve type
D) Changing valve plug mechanical configurations
B) Changing the valve
C) Changing the valve type
D) Changing valve plug mechanical configurations
Question 24:
Which is the applicable standard for enclosure ingress protection?
A) IEC 60079
B) IEC 60534
C) IEC 60584
D) IEC 60529
B) IEC 60534
C) IEC 60584
D) IEC 60529
Question 25:
Which codes/standards are being revised and/or already invoke the concepts of a Safety Instrumented Systems associated with Burner Management Systems:
A) NFPA 86
B) All of the answers
C) API 556
D) FM 7605 & EN50156-1
A) NFPA 86
B) All of the answers
C) API 556
D) FM 7605 & EN50156-1
Question 26:
Following is true for Controller in Auto Mode
A) Controller output tracks Setpoint
B) PV tracks set point
C) Controller output tracks PV
D) setpoint tracks PV
B) PV tracks set point
C) Controller output tracks PV
D) setpoint tracks PV
Question 27:
Select true statement for Non-contact type radar level transmitter
A) It can be used for fouling or corrosive services
B) It is used for products with dielectric constant >1.4
C) All are true statements
D) Do not use when the fluid surface is agitated or when foam may be formed
B) It is used for products with dielectric constant >1.4
C) All are true statements
D) Do not use when the fluid surface is agitated or when foam may be formed
Question 28:
Which configuration provides the best protection against nuisance shutdowns?
A) None of the answers
B) 1oo2
C) 2oo2
D) 1oo1
B) 1oo2
C) 2oo2
D) 1oo1
Question 29:
The direct-acting actuator is ________
A) Air to Open type actuator
B) Air to Close type actuator
C) Piston type actuator
D) applicable for the motorized actuator
B) Air to Close type actuator
C) Piston type actuator
D) applicable for the motorized actuator
Question 30:
2oo2 voting logic in fail-safe mode is following Gate
A) AND
B) XOR
C) OR
D) NAND
B) XOR
C) OR
D) NAND
Click on the below button to launch the Quiz.
Answers available in the Quiz.